    Huato Company provides real-time monitoring of the exhibition environment of the precious cultural relics, helping staff science Perceive the cultural relics to preserve the state of the environment. The control system equipment can regulate and control the inside environment, making sure the humidity inside is within preset range. By equipped a smart automatic water intake module developed by HUATO, the condensed water from dehumidification can be vaporize automatically. With automatic weater intake module, moisture inside can be condensed automatically and fill in inside tank, providing water for humidification. Through wireless communication,users can run multiple devices online flexibly.

    green-mi.png HUM2001 purification humidifier

     

    HUM2001 purification humidifier
    • Regulating volume: ≤2 m³ .
    • Moisture control accuracy: ≤±2% .
    • Humidity control range: the effective humidity control range is
      20%~70% when the temperature in the exhibition cabinet is lower than
      30℃ .
    • Power supply: DC12V/20A .
    • Rated power: ≤72W .
    • Air distribution: micro positive pressure air supply Purification
      mode: activated carbon filter adsorption Installation: install the
      bottom of the exhibition cabinet .
    • Fix the size with bracket :350x300x140mm .
    • Communication mode: reserve communication port RS485/RJ45, with
      built-in 2.4ghz wireless communication module .
    • Safety protection performance: automatic diagnosis and remote
      diagnosis function, multiple safety protection system.
     
     

     

    green-mi.png HUM2003 purification humidifier
    HUM2003 purification humidifier
    • Regulating volume :≤3~20 m³ .
    • Moisture control accuracy :≤±2% .
    • Humidity control range; Under the condition that the temperature in the exhibition cabinet is lower than 30℃, the effective humidity control range is 20%~70% .
    • Power supply :AC220V/50Hz .
    • Rated power :≤145W .
    • Air distribution: slightly positive pressure air supply .
    • Purification method: activated carbon filter adsorption .
    • Installation method: install the bottom of the exhibition cabinet and fix it with bracket .
    • Or: 450 x305x150mm .
    • Communication mode: reserve communication port RS485/RJ45, with built-in 2.4ghz wireless communication module .
    • Safety protection performance: automatic diagnosis and remote diagnosis function, multiple safety protection system.
     
    green-mi.png HUM2012/HUM2020 purification humidifier
    HUM2012/HUM2020 purification humidifier
    • Regulating volume :≤12/20m3 .
    • Moisture control accuracy: ≤±2% .
    • Humidity control range: the effective humidity control range is 20%~70% when the temperature in the exhibition cabinet is lower than 30℃.
    • Power supply :AC220V/50Hz .
    • Rated power: ≤210W~280W .
    • Air distribution: activated carbon filter adsorption in micro positive pressure air supply purification mode .
    • Communication mode: reserve communication port RS485/RJ45, with built-in 2.4ghz wireless communication module .
    • Safety protection performance: automatic diagnosis and remote diagnosis function, multiple safety protection system .
    • Installation method: install the bottom of the exhibition cabinet and fix it with bracket .
    • Or: 580 x500x160mm.
     
    green-mi.png Automatic multi-connection control system of water supply and drainage for purification and humidification machine
     
    • Tank volume :5 L, 10 L, 20 L, can be multiple linkage capacity expansion.
    • Water intake principle: it is equipped with automatic water intake device, which adopts the principle of heating air and then instantly cooling air to achieve the purpose of water intake.
    • Water quality alarm: built-in water quality detection device, the water quality does not meet the national standard level 2, start the alarm.
    • Safety design: the piping between the boxes is tightly connected to prevent water leakage and overflow, and has the function of water leakage alarm.

    A view of the humidified airport

    green-mi.png Environmental Monitoring Terminal
    • Enclosure protection level: The enclosure protection level of the monitoring terminal should at least meet the IP20 requirements specified in GB 4208.
    • Safety requirements:Meet the requirements of the safety requirements for preventive protective equipment for collections (T/WWXT 0004-2015).
    • Electromagnetic compatibility
    • Static immunity: It should meet the requirements of Class 2 and Class B criteria in GB/T 17626.2.
    • Radiation: It should meet the Class A limits of GB 9254.